upvc door frame cover

Our blinds aren’t solely designed just to cover your windows – you can use them on your doors as well! While most of our blinds are suitable to be fitted to your door frame, if you have a uPVC door, you may want to take a step back and think about which type of blind will be the best for you. You can drill into the uPVC frame quite easily to face-fix your blind to the door… But if you decide to change the type, style or size of blind you’re using at all, the frame could be left with some unsightly holes. So what can you do to avoid this? Designed to provide a perfect fit (just as the name suggests!) these aluminium venetian blinds are completely screw free – simply clipping in to the frame of the glass, using four to six brackets that simply slide between the glass panel and the beading of the door itself. Providing you have at least 6mm clearance between the glass and any handles, hinges or other obstructions, these blinds could be the perfect solution for you – once fitted, they can be raised, lowered and tilted either way just like our standard venetian blinds.

Our range of standard aluminium venetian blinds also come colour-matched so you can fully coordinate the look throughout your home! With a similar concept to our PerfectFit range shown above, these pleated blinds are designed to simply cover the glass panel completely. With a choice between our standard DuoLight range or the aluminium lined DuoShade range for additional blackout protection, these blinds are fitted in the same way as the PerfectFit blinds but without a frame around them. The great benefit of these blinds is that they are completely free hanging against the glass, so you can raise them from the bottom, lower them from the top or leave them suspended in the middle depending on where the sun is.You won’t need to screw these into your door frame either! All our vertical blinds have the option of being supplied with top-fixing brackets to attach to the underside of an alcove or the ceiling itself. You can choose which side the blinds open to as well, meaning that you can avoid any obstructions in front of the door handles, allowing you much easier access.

If you’re covering a double door- like a patio or french doors, you can even split the stack down the middle so it will open to either side, letting you make quite the entrance! So really, there is no need to despair- your uPVC doors can be catered for just as easily as your windows. Letter boxes / plates should be considered as an aperture which can be used by the criminal, either to extract goods from within in close proximity to the door, commonly door keys, or to work vulnerable locking devices from the inside.
lambo door kit for 2000 camaro Letter plates should conform to British Standard.
cheapest doors in sydneyThey should be positioned not closer then 400 mm from the door lock and under no circumstances should they be fitted to the bottom rail of the door.
garage door service wollongong

An internal cover plate offers additional security, as does a letter basket, though you might wish to consider removing the bottom, allowing the mail to fall to the floor and thus preventing theft of the mail. A rim latch (Yale type) on its own is not sufficient. The door should also be fitted preferably with a 5 lever mortice deadlock, though insurance companies will accept a rim automatic deadlock;
garage door opener barely movesboth must be to British Standard 3621 or the equivalent European Standard EN12209. Quality locks are only as strong as the doors and frames to which they are attached. Ensure that the frame is sound and the door suitable for external use; for instance, a wooden hollow core door would not be suitable. It should be of substantial construction, at least 44mm (13/4") thick to support the mortice lock and hung on three strong 100mm (4") hinges. The rim latch and the mortice should be fitted 45 to 60cm (18-24") apart.

In the door itself recessed or decorative panels should be a minimum of 9mm (1/3") thick. Consider fitting a London Bar (metal strip on frame side) to support the strike box, or Birmingham bar to support the frame on the hinge side. If the door is weak consider fitting a sheet steel plate or door reinforcer on the outside covering the lock area. Timber frames should be sound and securely bolted or screwed to the the walls every 600mm (23") around the whole frame. Doors with glazed panels are inherently less secure than solid doors, hence the need for a deadlock. Consider replacing ordinary or toughened glass panels with laminated glass - two pieces of glass bonded together with a sheet of laminate - as they offer much greater resistance to attack. For added safety and security fit a spy hole and door chain or limiter. These will enable you to deal with callers to your front door whilst retaining a level of security. UPVC/PVCU front doors are generally unsuitable for retro-fit security devices.

Not only is the material not strong enough to support devices fitted with steel screws unless secured into the internal metal framework, but such changes to the original design may invalidate an existing warranty or possibly damage the integral locking assembly. If in doubt, consult the installer/manufacturer. Modern designs will usually incorporate deadlock shoot bolts or a multi-point locking system, both throwing a number of bolts from the door into the frame. Under these circumstances there will not normally be any need for additional devices. Advice on front door security while the house is occupied will vary, depending on whom you speak to. Fire Safety Officers will advise that, for safety reasons, the mortice deadbolt should not be engaged when the house is occupied, as locating and engaging the key can cause unnecessary delay in escaping from the scene of a fire. Crime Prevention Officers may suggest that a rim latch on its own is insufficient in providing adequate security and that engaging the lock would increase this, as well as the safety of young children in preventing them from wandering.

Clearly these are issues which need to be considered. If you feel fire safety is the priority, additional security can be obtained by fitting draw bolts to the top and bottom of the door. The door should be fitted with a 5 lever 2 bolt mortice sash lock halfway up the door, (a deadlock with a handle for convenience). Unlike front doors, many insurance companies do not specify that they should be to British Standard 3621 or equivalent European Standard EN 12209, though the use of this standard of lock is recommended. The sash lock should be supplemented by mortice rack bolts (bolts fitted approximately 150mm (6") from the top and bottom of the door into the wood and operated internally) or surface-mounted locking bolts top and bottom. They should always be fitted at 90º to the grain of the wood, reducing the likelihood of the wood splitting if subjected to pressure. Any glass panels should be laminated and fitted from the inside to prevent the putty or beading being removed.

Grilles could also be fitted to the inside of the panels. Also known as French windows, they are intrinsically less secure than single leaf doors, which may reflect on their comparative lack of popularity as compared with the modern patio door. However, this need not be the case provided that suitable security measures are taken. Both doors should be fitted with mortice rack bolts (bolts fitted within the door and operated internally by a threaded key). They should always be fitted at 90 º to the grain of the wood, reducing the likelihood of the wood splitting if subjected to pressure. Alternatively, use surface-mounted locking bolts (push to lock, key to open). Whichever type you use, fit top and bottom to provide rigidity. If the style of door is capable of it, a mortice sash lock can be fitted for extra security (rebate sets may also be required). As most French Doors are outward opening, the addition of hinge bolts is also recommended. They should be located 100-150mm (4-6") below the top hinge and similarly above the bottom.

Note: It would be acceptable, for insurance purposes, for key operated bolts only to be fitted top and bottom of both doors. Consider replacing ordinary or toughened glass panels with laminated glass - two pieces of glass bonded together with a sheet of laminate - as they offer much greater resistance to attack. UPVC/PVCU French doors are generally unsuitable for retro-fit security devices. Entry through a patio door is a common means of entry and therefore, unless the doors are fitted with a multi-locking system, it is best to fit extra locks. These are fitted on the bottom fixed frame pushing through to the sliding frame in the centre and on the side frame at the opening point no lower than a third of the way from the top of the door. Most such locks are push to lock and key to open and are therefore easy to use. Make sure there is enough frame to fit them on if drilling is required. If in doubt, consult the installer or manufacturer. A dual screw can be fitted between both frames but it is more awkward to use, so there can be a tendency to leave it unlocked, thus defeating the object.